Offering a UL 142 single wall/ double wall fuel storage tank. Aboveground storage tanks are designed and engineered to meet the demanding needs of many industries for backup or main storages & daily fuel storage tank.
Offering FIREGUARD double-wall fire-protected aboveground storage tank features an inner and outer steel tank with a unique lightweight thermal insulation material that exceeds the UL 2-hour fire test UL 2085 Listed “Protected” tank. Ballistics and Impact protection per UL 2085 Both the inner and outer steel tanks are built to UL standards. National Fire Protection Association (NFPA) 30 & 30A International Fire Code (IFC).
Offering a secondary contained tank comprised of a steel primary inner tank enclosed within a 360-degree Fiberglass Reinforced Plastic (FRP) outer tank, ensures that the tank will comply with all current and future legislation. Product compatibility and structural strength are ensured by the steel inner tank.
100% polyurethane dielectric coating, Electrical isolation Factory-installed cathodic protection system using sacrificial anodes UL-58 and UL-1746 compliant Available in single or double-wall Maximum 120° F temperature rating.
It combines the strength of steel with a three-way protection system: 100% polyurethane dielectric coating, Electrical isolation Factory-installed cathodic protection system using sacrificial anodes UL-58 and UL-1746 compliant Available in single or double-wall Maximum 120° F temperature rating.
Tanks confirming to BS 799, BS 12285, BS 2594 Standard. Aboveground and Underground tanks type included, Services tanks and Primary storage tanks with capacity of 90 litre or more with maximum height of 10 meter as complied by standard.
The standard API 650 covers the design and calculation of the different elements of the tank. In view of the materials of construction, requirements and recommendations are set forth, i.e. erection sequences, welding procedures, tests and inspections as well as guidelines for operation. Tanks in which liquid fluids are stored and designed to withstand atmospheric pressure operation, less than 18 kPa, or internal pressures not exceeding the weight of the roof, with temperatures no higher than 93, 3 ° C are included in the scope of this design code. Internal temperatures could go up to 260 ° C with certain restrictions.
Vertical cylindrical flat bottom tanks allow us to store large volumetric quantities at low cost, with the only limitation that they can only be used at atmospheric pressure or relatively small internal pressures.
High quality, dimensionally exact pre-fabrication of spool piping. Industrial process piping, including oil & gas, chemical, utility, and sanitary grades.
Floor fabrication of steel structures for the chemical, petrochemical and cement industries.